Casino Matrix Dua

Posted on

Login to read unlimited. books, audiobooks, magazines, Snapshots and access to tens of millions of documents.

MatriXX ionization chamber detector arrays are designed for fast and accurate verification of patient dose and Linac QA.

  • Casino Matrix CONCEPT SERIES: Inspired by a hybrid of Xerjoff Nio & Maison Francis Kurkdjian Baccarat Rouge 540 Extrait with an added note of Iso-E-Super. The Italian countryside reminds us that nature is alive and well as bergamot trees line the fields and their aromatic enchantment sends us into a gratifying stupor.
  • CASINO M8TRIX event tower luxurious Meeting and event spaces Located on the fifth, sixth, and seventh floors of Casino M8trix’s high rise building, our luxurious meeting and event spaces provide picturesque views of Silicon Valley and are ideal for social events, corporate events, and non-profit gatherings. Accepting groups of 14 or more.
  • Unique universal detector for Patient QA and Machine QA: both applications powered by the myQA - global QA platform
  • Fast and intuitive, from measurement setup to analysis
  • Most accurate for rotational and IMRT QA: shortest 20ms data sampling time, high dose rate, and high spatial resolution with 1020 ionization chambers
  • Most reliable solution with more than 1500 systems in the world

MatriXX for Varian® HalcyonTM 1)

The MatriXX solution with miniPhantom and myQA Patients is your ideal solution for efficient Halcyon1) patient plan verification.

Pictured: MatriXX and miniPhantom setup for patient QA

'For our new Varian® Halcyon 1) machine we evaluated our MatriXX ionization chamber array with the miniPhantom. The patient QA measurements and evaluation in myQA Patients have been very good.”

Maciej Raczkowski
Head of the Dosimetry and Quality Control
Lower Silesia Center od Oncology in Wrocław, Poland

Description

MatriXX with myQA Patients is the solution for high dose rate and rotational 2D plan verification.

MatriXX is a universal detector also suited for Machine QA.

MatriXX Evolution

Proven detector based on more than 1500 MatriXX systems worldwide

  • Combine with the miniPhantom and Gantry Angle Sensor to attain the most accurate measurements for verification with myQA Patients.
  • Optimized for conventional, IMRT, and rotational cases delivered in standard dose rate mode.
  • Also suitable for high-dose-rate cases (up to 12 Gy/min).

MatriXX FFF

Casino Matrix Dua

Ultimate High-Dose-Rate Solution (up to 48 Gy/min)

  • Fast: High-end design for workflow efficiency, from setup to measurement and analysis.
  • Flexible: Determined for high-dose-rate (up to 48 Gy/min), Flattening-Filter-Free, and conventional measurements.
  • FFF Proven: Supports current and future high-dose-rate delivery systems including Varian®, Elekta®, and Siemens®.

MatriXX Evolution

  • Compatible with the Varian® Halcyon™ and Ethos™ System1)
  • Sensor type: Vented parallel ion chamber
  • Number of sensors: 1020, arranged in a 32 × 32 grid except for the 4 corner positions
  • Active measurement area: 24.4 cm × 24.4 cm
  • Chamber diameter: 4.5 mm
  • Chamber height: 5.0 mm
  • Chamber volume: 80 mm3
  • Distance between chambers: 7.62 mm (center to center)
  • Nominal sensitivity: 2.4 nC/Gy
  • Collection efficiency (pulsed beam at 300 Hz - 360 Hz PRF): ≥ 99.0% at 0.3 mGy/pulse, ≥ 98.5% at 0.6 mGy/pulse, ≥ 97.0% at 1.1 mGy/pulse
  • Dose Rate Range: 0.02 – 12 Gy/min
  • Dose Rate Dependence: < ±1.0%
  • Dose Range: 0 – 10 Gy
  • Bias voltage: 500 ± 30 V
  • Absorber material on top: 3 mm ABS Tecaran (density 1.06 g/cm3)
  • Water equivalent depth: 3.1 mm
  • Effective point of measurement (Peff): 3.5 mm below the surface, indicated by engraved markers on the housing sides.
  • Deviation from Linearity: ≤ 1% for dose ≥ 0.02 Gy

MatriXX FFF

  • Compatible with the Varian® Halcyon™ and Ethos™ System1)
  • Sensor type: Vented parallel ion chamber
  • Number of sensors: 1020, arranged in a 32 × 32 grid except for the 4 corner positions
  • Active measurement area: 24.4 cm × 24.4 cm
  • Chamber diameter: 4.5 mm
  • Chamber height: 2.0 mm
  • Chamber volume: 32 mm3
  • Distance between chambers: 7.62 mm (center to center)
  • Nominal sensitivity: 1.4 nC/Gy
  • Maximum dose rate: 48 Gy/min
  • Charge collection efficiency (pulsed beam at 300 Hz PRF): ≥ 99.0% at (1.0 mGy/pulse), ≥ 98.5% at (2.0 mGy/pulse)
  • Minimum dose rate: 0.02 Gy/min
  • Bias voltage: 500 ± 30 V
  • Absorber material on top: 6 mm ABS Tecaran (density 1.06 g/cm3)
  • Water equivalent value: 6.4 mm
  • Effective point of measurement (Peff): 6.5 mm below the surface, indicated by engraved markers on the housing sides.
  • Deviation from Linearity ≤ 1% if dose ≥ 0.15 Gy

1 All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any relationship, sponsorship, or endorsement between IBA or its products and the owners of these trademarks.

Integrated Machine QA Brochure
(11.71 MB)

Related Products

MatriXX Resolution*

Highest resolution for IMRT & VMAT
Patient QA measurements
and Machine QA

Discover

myQA® SRS*

Accuracy of film QA.
Efficiency of a digital detector array.

Discover

COMPASS

2-in-1 Patient Dose QA in
3D Patient Anatomy

Discover

myQA HALO Package
for Ethos™️ / Halcyon™ ¹

The commissioning and beam data collection
package for the Varian® Halcyon™/Ethos™ ¹ machine.

Discover

miniPhantom

Phantom-Based Patient QA with
MatriXX Detectors or Films

Casino Matrix Happy Hour

Discover

myQA Patients

Patient QA solution for gamma verification of dose distributions

Discover

myQA Machines

Integrated protocol-based QA

Discover

Casino Matrix Address

myQA® SRS

Accuracy of film QA. Efficiency of a digital detector array.

The digital SRS/SBRT Patient QA Solution